Oct 8 – 12, 2010
Cornell University Statler Hotel
America/New_York timezone

Implementation and Operation of Electron Cloud Diagnostics for CesrTA

Oct 10, 2010, 3:30 PM
2h
Foyer (Cornell University Statler Hotel)

Foyer

Cornell University Statler Hotel

Board: 3

Speaker

Dr Yulin Li (CLASSE, Cornell University)

Description

The vacuum system of Cornell Electron Storage Ring (CESR) was successfully reconfigured to support CesrTA physics programs, including electron cloud (EC) build-up and suppression studies. One of key features of the reconfigured CESR vacuum system is the flexibility for exchange of various vacuum chambers with minimized impact to the accelerator operations. This is achieved by creation of three short gate-valve isolated vacuum sections. Over the last three years, many vacuum chambers with various EC diagnostics (such as RFAs, shielded pickups, etc) were rotated through these short experimental sections. With these instrumented test chambers, EC build-up was studied in many magnetic field types, including dipoles, quadrupoles, wigglers and field-free drifts. EC suppression techniques by coating (TiN, NEG and a-C), surface textures (grooves) and clearing electrode are incorporated in these test chambers to evaluate their effectiveness. We present the implementation and operations of EC diagnostics.

Primary author

Dr Yulin Li (CLASSE, Cornell University)

Co-authors

Mr Joseph Conway (CLASSE, Cornell University) Mr Valery Medjidzade (CLASSE, Cornell University) Dr Xianghong Liu (CLASSE, Cornell University)